Syringeless and Syringe Filters
Syringeless and Syringe Filters
- (2)
- (17)
- (15)
- (4)
- (1)
- (39)
- (38)
- (18)
- (12)
- (4)
- (1)
- (4)
- (5)
- (7)
Filtered Search Results
Merck Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Modified Acrylic |
Material (Membrane) | PES |
Color | Green |
Pressure Rating | 145 psi |
Material | PES |
For Use With (Application) | Low protein binding; sterilization of tissue culture media, protein solutions or aqueous solutions; Sterilization of drugs or aqueous solutions administered intravenously |
Sterility | Sterile |
Type | Modified Acrylic Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lok |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Filter Type | Membrane Filter |
Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Merck Millex™-GV Sterile Syringe Filter Unit, PVDF, 0.22 μm
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | PVDF |
Color | Yellow |
Material | Durapore PVDF |
For Use With (Application) | Ultra-low protein binding; Sterilization of tissue culture media, protein solutions or aqueous solutions |
Sterility | Sterile |
Type | Syringe Filter |
Inlet Style | Female Luer Lok |
Temperature Range (English) | 113°F |
Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Merck Millex™-GS Sterile Syringe Filter Unit, MCE, 0.22 μm
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Designed for sterilizing and clarifying sterile solutions. Millex™ Sterile Syringe Filters: MCE Membrane are ready-to-use, syringe-driven units that have never been touched by human hands during filter assembly. Feature 0.22, 0.45 and 0.80μm pore sizes; medical-grade filters available.
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Mixed Cellulose Esters (MCE) |
Color | Blue |
Pressure Rating | 145 psi |
Material | Mixed Cellulose Esters (MCE) |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Inlet Style | Female Luer Lok |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Merck Millex™-HV Sterile Syringe Filter Unit, PVDF, 0.45 μm
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions are available in 0.1, 0.22, 0.45 and 5.0μm pore sizes
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | PVDF |
Color | Yellow |
Material | Durapore PVDF |
Sterility | Sterile |
Outlet Style | Male Luer Slip |
Inlet Style | Female Luer Lok |
Temperature Range (English) | 113°F |
Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Merck Millex-GP Syringe Filter Unit
Millex-GP Syringe Filter Unit for sterilization of tissue culture media, protein solutions or aqueous solutions.
Merck Millex™-GV Sterile Syringe Filter Unit, PVDF, 0.22 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | PVDF |
Color | Yellow |
Material | Durapore PVDF |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Inlet Style | Female Luer Lok |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Merck Millex™-VV Sterile Syringe Filter Unit, PVDF, 0.1 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
Merck Millex™-SV Sterile Syringe Filter Unit, PVDF, 5.0 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions are available in 0.1, 0.22, 0.45 and 5.0μm pore sizes
Merck Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Hydrophilic PES |
Color | Green |
Volume (Metric) | <10 mL |
Pressure Rating | 145 psi |
Material | PES |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Modified Acrylic Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lok |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Merck Millex™-GS Sterile Syringe Filter Unit, MCE, 0.22 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Designed for sterilizing and clarifying sterile solutions. Millex™ Sterile Syringe Filters: MCE Membrane are ready-to-use, syringe-driven units that have never been touched by human hands during filter assembly. Feature 0.22, 0.45 and 0.80 μm pore sizes.
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Mixed Cellulose Esters (MCE) |
Color | Blue |
Pressure Rating | 145 psi |
Material | Mixed Cellulose Esters (MCE) |
For Use With (Application) | Clarification of water, buffers or aqueous solutions |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lok |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Merck Millex™-HA Sterile Syringe Filter Unit, MCE, 0.45 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Designed for sterilizing and clarifying sterile solutions. Millex™ Sterile Syringe Filters: MCE Membrane are ready-to-use, syringe-driven units that have never been touched by human hands during filter assembly. Feature 0.22, 0.45 and 0.80μm pore sizes; medical-grade filters available.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Mixed Cellulose Esters (MCE) |
Material (Membrane) | MCE |
Color | Blue |
Volume (Metric) | 100 mL |
Pressure Rating | 145 psi |
Material | Mixed Cellulose Esters (MCE) |
For Use With (Application) | Clarification of water, buffers or aqueous solutions |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lok |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Filter Type | Membrane Filter |
Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <100 μL |
Merck Millex™-HP Sterile Filter Unit, PES, 0.45 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
A 33 mm diameter sterile syringe filter with a 0.45 μm pore size hydrophilic Polyethersulfone (PES) membrane.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Housing Material | Modified Acrylic |
Volume (Metric) | 200 mL |
Diameter (Metric) Membrane | 33 mm |
For Use With (Application) | Low protein binding; sterilization of tissue culture media, protein solutions or aqueous solutions |
Sterility | Sterile |
Merck Millex™-HV Sterile Syringe Filter Unit, PVDF, 0.45 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions are available in 0.1, 0.22, 0.45 and 5.0 μm pore sizes.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | PVDF |
Color | Yellow |
Volume (Metric) | 100 mL |
Material | Durapore PVDF |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Inlet Style | Female Luer Lok |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Merck Millex™-HP Sterile Polyethersulfone Syringe Filter Units, 0.45 μm (Research Use Only)
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (English) Operating | 113°F |
Housing Material | Hydrophilic PES |
Material (Membrane) | PES |
Color | Green |
Volume (Metric) | 100 mL |
Pressure Rating | 145 psi |
For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
Sterility | Sterile |
Type | Syringe Filter |
Outlet Style | Male Luer Slip |
Diameter (Metric) | 3.3 cm |
Inlet Style | Female Luer Lok |
Tip Material | Modified Acrylic |
Temperature Range (English) | 113°F |
Temperature Range (Metric) | 45°C |
Temperature (Metric) Operating | 45°C |
Autoclavable | Not Autoclavable |
Hold up Volume (After Air Purge) | <0.1 mL |
Merck Millex™-VV Sterile Syringe Filter Unit, PVDF, 0.1 μm
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions are available in 0.1, 0.22, 0.45 and 5.0μm pore sizes